Systems

The same platform, at three scales.

Module, rack and block are designed together. Buy the layer that fits your scope — a pack-level supplier, a systems integrator or a full EPC client.

ChemistryLFP (LiFePO4)
Nominal energy8.04 kWh → 5.016 MWh
DC architecture25.6 V → 1,331.2 V

01 · Module

Module 8.0

8S1P

The repeatable unit of everything we build: 314 Ah LFP prismatic cells in an 8S1P block on an aluminium cold plate, with cell-level fusing and laser-welded busbars. Serviceable in rack without breaking the coolant loop.

  • Cell-level fusingA single cell failure is contained at module level, not passed up the string.
  • Cold-plate coolingLiquid cooling on the module base keeps cell delta-T inside 3 K across the rack.
  • Serialised to the cellEvery module carries a serial tied to its cell lot, test data and destination rack.

Request module datasheet

Module outline, 8S1P: eight cells in two rows inside an aluminium frame with a cold plate, 810 by 420 millimetres. 810 mm 420 mm 8 × 314 Ah LFP 8S1P
Fig. 03 — Module envelopeIndicative
Technical specification — Module 8.0
Configuration8S1P
Nominal energy8.04 kWh
Nominal voltage25.6 V
Voltage window20.0 – 29.2 V
Capacity314 Ah
ChemistryLFP (LiFePO4)
Continuous C-rate0.5C charge / 0.5C discharge
Cycle life6,000 to 80% SoH
CoolingLiquid cold plate
EnclosureIP20, serviceable in rack
Dimensions (W×D×H)810 × 420 × 220 mm
Mass≈ 58 kg

02 · Rack

Rack 418

1P416S

Fifty-two modules on a steel rack with a rack-level BMS, DC breaker and coolant manifold. 1,331.2 V nominal — the voltage class that lets a standard 20-ft container hold 5 MWh.

  • Three-level BMSCell, rack and block layers each report state of charge, state of health and insulation.
  • Serviceable in placeModules withdraw from the front; the coolant loop stays closed and the rack stays on bus.
  • Open protocolsModbus RTU/TCP as standard, CAN internally. IEC 61850 available for utility SCADA.

Request rack datasheet

Technical specification — Rack 418
Configuration1P416S · 52 × Module 8.0
Nominal energy418 kWh
Nominal voltage1,331.2 V DC
Voltage window1,040 – 1,498 V DC
Continuous power209 kW at 0.5C
CoolingLiquid, 50/50 glycol-water
Cell delta-T≤ 3 K in steady state
ProtectionDC breaker, fuse, contactor, insulation monitoring
CommunicationModbus RTU / TCP, CAN 2.0
Dimensions (W×D×H)1,200 × 800 × 2,300 mm
Mass≈ 3,100 kg
InstallationInside ISO container or IP54 enclosure

03 · Block

Block 5.0

5.016 MWh

A complete DC block: twelve racks, thermal management, detection and suppression, deflagration venting and a single DC interface — built, wired and tested in Ahmedabad before it is shipped.

  • Factory acceptance testedCapacity, round-trip efficiency, insulation resistance, thermal performance and comms, witnessed and recorded.
  • Layered fire protectionMulti-sensor detection, clean-agent suppression and deflagration venting designed to NFPA 855 logic.
  • One interfaceA single DC connection and one communications port. No site-side assembly of racks.

Request block datasheet

Representative render of the Block 5.0 container
Fig. 04 — Block 5.0Representative render
Technical specification — Block 5.0
Configuration12 × Rack 418
Nominal energy5.016 MWh
Nominal DC voltage1,331.2 V
Continuous power2.5 MW at 0.5C
DC round-trip efficiency≥ 95%
Thermal managementLiquid cooling + HVAC for auxiliaries
Fire detectionAspirating smoke, VOC, cell temperature
SuppressionClean agent, per-rack and plenum
Enclosure20-ft ISO, IP55, C4-M corrosion class
Operating ambient−20 to +50 °C (derated above 45 °C)
Altitude≤ 2,000 m without derating
CommunicationModbus TCP, IEC 61850 (option)
Mass≈ 43 t

Comparison

Side by side.

Values below are nominal at beginning of life. The project datasheet governs — it is issued for the exact configuration, market and warranty term you procure.

Parameter Module 8.0 Rack 418 Block 5.0
Nominal energy8.04 kWh418 kWh5.016 MWh
Configuration8S1P1P416S12 racks
Nominal voltage25.6 V1,331.2 V1,331.2 V
Continuous power (0.5C)4 kW209 kW2.5 MW
CoolingCold plateLiquidLiquid + HVAC
EnclosureIP20IP20IP55, 20-ft ISO
Mass≈ 58 kg≈ 3,100 kg≈ 43 t
Supplied toRack integratorsContainer builders, C&I integratorsUtilities, IPPs, EPC clients

Manufacturing tolerances and site conditions can move these figures. Always procure against the issued project datasheet, not this page.

Configuration

What we change per project.

The battery platform is fixed — that is what makes the test data repeatable. Everything around it is selected against your connection study and commercial model.

Plant size

2 to 40 blocks per plant, in 5 MWh steps, subject to layout and fire separation.

PCS & transformer

Selected to your grid code, fault level and reactive-power requirement — not bundled by default.

Cooling

Liquid cooling as standard; air-cooled variants for low-duty C&I cycles.

Controls

Modbus TCP, IEC 61850 or a full EMS/SCADA layer with revenue-grade metering.

Fire strategy

Detection and suppression specified to the applicable code set — NFPA 855, local fire authority or both.

Warranty

5 years standard, extendable to 15 with a throughput and capacity-retention schedule.

Datasheets

Documents, issued against your project.

We do not publish undated PDFs. A datasheet is issued for the exact configuration, market and warranty term you are procuring, with the revision recorded on the document. Ask for one and you will get the version that applies to you.

Product datasheet

Configuration, curves, derating and compliance references.

Qualification pack

Standards framework, test regime, FAT procedure and traceability.

Drawings

GA and interface drawings for civil, electrical and fire design.

O&M

Service schedule, spares list and warranty terms.

Request documents

Next step

Not sure which layer you need?

Send the load profile, the site and the required hours of storage. We will tell you the block count — and whether you should be buying modules, racks or a full block.